New Zealand Β· costs in NZD

Reverse cycle split system air conditioner, under ceiling
Mitsubishi Electric PUZ-ZM140YKA-A/PCA-M140KA Series Heat Pump
Mitsubishi Electric PUZ-ZM140YKA-A/PCA-M140KA Series is a 13.5 kW reverse cycle split system heat pump registered for sale in New Zealand under the trans-Tasman E3 energy rating scheme (registration AAC7886).
- Energy rating (cooling)
- 2
- Heating: 1.5
- Annual electricity use
- 7,449 kWh
- 911 cooling + 6,538 heating
- Estimated running cost
- $2,458 / year
- $205 / month Β· $24,582 over 10 years
- Capacity
- 13.5 kW cooling
- 16 kW heating
12% more electricity than the median of 66 comparable 14 kW reverse cycle split system registrations (6,658 kWh a year) in the cold zone. Uses less than 17% of them.
Across all 3,611 air conditioner registrations sold in Australia, it uses less than 22% (this compares very different sizes, so the cohort figure above is the useful one).
Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ 33c/kWh in NZD; change the price above to your tariff.
Mitsubishi Electric running cost by climate zone
| Climate zone | kWh / year | Per year | 10 years |
|---|---|---|---|
| Cold zone | 7,449 | $2,458 | $24,582 |
| Mixed zone | 3,765 | $1,242 | $12,425 |
| Hot zone | 4,318 | $1,425 | $14,249 |
At 33c/kWh. Formula: cost = annual kWh Γ price. The kWh figure is the labelβs residential estimate for that zone; commercial-profile figures are in the specifications.
Heat pumps that use less electricity
Same configuration and type, cooling capacity within 12% of 13.5 kW, at least 3% lower annual kWh in the cold zone.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-125PZ4R8 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 | |
| Panasonic U-125PZ4R5 / S-1014PU3E12.5 kW heating12.5 kW cooling4,631 kWh/yr | 3 | $1,528 | |
| Mdv C-UV-125N8-QC3W / CSV-125N8-QC3W13 kW heating12.5 kW cooling5,013 kWh/yr | 4 | $1,654 | |
| Kaden KDI42 / KCI4213 kW heating12.5 kW cooling5,013 kWh/yr | 4 | $1,654 | |
| Daikin RZAV125FV1 / FCTA125AVMA15 kW heating12.5 kW cooling5,020 kWh/yr | 4 | $1,657 |
Heat pumps similar to the Mitsubishi Electric
Technically comparable registrations: same configuration and type, capacity within 12%.
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Panasonic U-140PZ4R5 / S-1014PT3E14 kW heating13.6 kW cooling5,971 kWh/yr | 2.5 | $1,970 | |
| Panasonic U-140PZ4R8 / S-1014PT3E14 kW heating13.6 kW cooling5,971 kWh/yr | 2.5 | $1,970 | |
| Mitsubishi Heavy Industries FDC(A)140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr | 2.5 | $2,162 | |
| Mitsubishi Heavy Industries FDCA140VSX-W / FDE140VH16 kW heating14 kW cooling6,552 kWh/yr | 2.5 | $2,162 | |
| Fujitsu AOTH54KBTA/ABTH54KRTA15.5 kW heating13 kW cooling6,247 kWh/yr | 3 | $2,062 | |
| Hisense AUW-140U4RN1/ AUC-140U4RKC115 kW heating13.5 kW cooling8,256 kWh/yr | 2.5 | $2,724 |
Other Mitsubishi Electric models of similar capacity
| Model | Stars | Est. cost / yr | Compare |
|---|---|---|---|
| Mitsubishi Electric PUZ-ZM140VKA2-A/PCA-M140KA216 kW heating13.5 kW cooling6,597 kWh/yr | 2 | $2,177 | |
| Mitsubishi Electric PUZ-ZM140VKA-A/PCA-M140KA Series16 kW heating13.5 kW cooling6,597 kWh/yr | 2 | $2,177 |
Compare PUZ-ZM140YKA-A/PCA-M140KA Series with another model
Mitsubishi Electric specifications
- Type
- Reverse cycle
- Configuration
- Split system
- Air distribution
- Non-ducted
- Indoor unit
- Under ceiling
- Rated cooling capacity (35 Β°C)
- 13.50 kW
- Cooling power input
- 4.15 kW
- Rated heating capacity (7 Β°C)
- 16.00 kW
- Heating power input
- 4.72 kW
- EER, full load (tested)
- 3.65
- COP, full load (tested)
- 3.77
- Rated AEER
- 3.17
- Rated ACOP
- 3.31
- Standby power (PIA)
- 33.6 W
- Compressor
- Variable speed, Inverter
- Refrigerant
- R32
- Power supply
- Three phase
- Indoor sound power
- β
- Outdoor sound power
- β
- Demand response (AS/NZS 4755)
- Yes (mode 1 on off, mode 2 50 percent, mode 3 75 percent)
- Dimensions (WΓHΓD)
- 1600 Γ 230 Γ 680 mm
- Country of manufacture
- Thailand
Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.
Mitsubishi Electric zoned energy rating figures
As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.
| Zone | Profile | Cooling stars | Heating stars | Cooling kWh | Heating kWh |
|---|---|---|---|---|---|
| Coldcommercial | commercial | β | β | 1,883 | 2,039 |
| Coldresidential | residential | 2.0 | 1.5 | 911 | 6,538 |
| Mixedcommercial | commercial | β | β | 2,365 | 1,046 |
| Mixedresidential | residential | 2.0 | 2.0 | 1,408 | 2,357 |
| Hotcommercial | commercial | β | β | 5,211 | 255 |
| Hotresidential | residential | 2.5 | 2.5 | 3,935 | 383 |
Part-load test points (16 values)
- h__h2_ext_cap_power_rated
- 5840 W
- c__t1_half_cap_power_rated
- 1430 W
- c__t1_have_min_cap_results
- No
- h__h1_half_cap_power_rated
- 1630 W
- h__h1_have_min_cap_results
- No
- h__h3_have_ext_cap_results
- No
- h__h2_have_full_cap_results
- No
- h__h2_have_half_cap_results
- No
- h__h3_have_full_cap_results
- No
- h__h3_have_half_cap_results
- No
- h__h2_ext_cap_heat_cap_rated
- 13200 W
- h__h1_half_cap_heat_cap_rated
- 8000 W
- h__h2_is_capable_extended_load
- Yes
- c__low_temp_have_min_cap_results
- No
- c__t1_half_cap_cooling_cap_rated
- 6750 W
- c__low_temp_have_half_cap_results
- No
Other model numbers on registration AAC7886
Registered together and sharing the same test results. Usually variants of the same unit.
New Zealand E3 registration details
- Registration number
- AAC7886
- GEMS registration id
- 157865
- Status
- approved, available (self-reported)
- Registration expires
- 14 November 2028
- Registered for sale in
- Australia, New Zealand
- Family
- PUZ-ZM140YKA-A/PCA-M140KA Series
- Regulatory standard
- [SEER Non Multi-Split <=65kW] GEMS (Air Conditioners up to 65kW) Determination 2019
- Test standard
- AS/NZS 3823.1.1:2012
- MEPS
- 2019
- Product class
- Class 11
Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 25 September 2026; last checked 26 September 2026. Manufacturer: MitsubishiElectric.com.au. How the derived figures are calculated.