c/kWh
Energy rating (cooling)
3.5
Heating: 2
Annual electricity use
6,186 kWh
707 cooling + 5,479 heating
Estimated running cost
$2,041 / year
$170 / month Β· $20,414 over 10 years
Capacity
14 kW cooling
16 kW heating

8% less electricity than the median of 124 comparable 14 kW reverse cycle ducted split system registrations (6,763 kWh a year) in the cold zone. Uses less than 83% of them.

Across all 3,612 air conditioner registrations sold in Australia, it uses less than 30% (this compares very different sizes, so the cohort figure above is the useful one).

coolingheatingClick a zone to use it across the page.

Annual kWh is the government label figure for a residential user in the cold zone (Canberra climate: Canberra, Hobart, Ballarat, alpine areas). All of New Zealand is the cold zone on the Zoned Energy Rating Label. Cost = kWh Γ— 33c/kWh in NZD; change the price above to your tariff.

Rinnai DSNSR15B1LA running cost by climate zone

Climate zonekWh / yearPer year10 years
Cold zone 6,186$2,041$20,414
Mixed zone 3,128$1,032$10,322
Hot zone 3,492$1,152$11,524

At 33c/kWh. Formula: cost = annual kWh Γ— price. The kWh figure is the label’s residential estimate for that zone; commercial-profile figures are in the specifications.

Heat pumps that use less electricity

Same configuration and type, cooling capacity within 12% of 14 kW, at least 3% lower annual kWh in the cold zone.

ModelStarsEst. cost / yrCompare
Daikin RZA160CV1 / FDYAN160AV118 kW heating15.5 kW cooling4,493 kWh/yr2$1,483
Panasonic U-125PZ4R5 / S-125PE4RN12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Panasonic U-125PZ4R5 / S-125PE4*12.5 kW heating12.5 kW cooling4,742 kWh/yr3$1,565
Midea DUCMI125IHB/UCMI125OB13 kW heating12.5 kW cooling4,776 kWh/yr4$1,576
Rinnai DONSR13B1/DINLR13B113 kW heating12.5 kW cooling4,830 kWh/yr4$1,594

Heat pumps similar to the Rinnai DSNSR15B1LA

Technically comparable registrations: same configuration and type, capacity within 12%.

ModelStarsEst. cost / yrCompare
Kaden KDI-14.015.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Mdv C-UV-140N8-QC3W / CDV-140HFN8-QC3W14.5 kW heating14 kW cooling5,664 kWh/yr4$1,869
Kaden KDI48 / KDI4814 kW heating14 kW cooling5,394 kWh/yr4$1,780
Midea DUCMI140IHB/UCMI140OB14.5 kW heating14 kW cooling5,596 kWh/yr4$1,847
Actron Air URC-140DS / LRE-140DS15.5 kW heating14 kW cooling5,768 kWh/yr4$1,903
Actron Air URC-140CS / LRE-140CS14.3 kW heating14 kW cooling5,513 kWh/yr4$1,819
Mdv C-UV-140N8-QC3W / CDV-140A6N8-QC3W14.5 kW heating14 kW cooling5,607 kWh/yr3.5$1,850
Midea UCMI140OB/DUCMI140IHB14.5 kW heating14 kW cooling5,658 kWh/yr4$1,867

Compare DSNSR15B1LA with another model

Rinnai DSNSR15B1LA specifications

Type
Reverse cycle
Configuration
Split system
Air distribution
Ducted
Indoor unit
–
Rated cooling capacity (35 Β°C)
14.00 kW
Cooling power input
4.25 kW
Rated heating capacity (7 Β°C)
16.00 kW
Heating power input
4.10 kW
EER, full load (tested)
3.31
COP, full load (tested)
3.98
Rated AEER
3.27
Rated ACOP
3.87
Standby power (PIA)
9.0 W
Compressor
Variable speed, Inverter
Refrigerant
R32
Power supply
Single phase
Indoor sound power
–
Outdoor sound power
70.8 dB(A)
Demand response (AS/NZS 4755)
Yes
Country of manufacture
China

Dimensions are not collected for registrations under the 2019 Determination, so they are shown only where the source has them.

Rinnai DSNSR15B1LA zoned energy rating figures

As published for each climate zone. Residential figures drive the star ratings; commercial figures assume a commercial usage pattern.

ZoneCooling starsHeating starsCooling kWhHeating kWh
Coldcommercial––6541,702
Coldresidential3.52.07075,479
Mixedcommercial––1,294873
Mixedresidential3.52.51,1252,003
Hotcommercial––3,403184
Hotresidential4.03.53,205287
Part-load test points (23 values)
c__t1_min_cap_power_rated
920 W
h__h1_min_cap_power_rated
643 W
h__h2_ext_cap_power_rated
5100 W
c__t1_half_cap_power_rated
2100 W
c__t1_have_min_cap_results
Yes
h__h1_half_cap_power_rated
1460 W
h__h1_have_min_cap_results
Yes
h__h3_have_ext_cap_results
No
h__h2_have_full_cap_results
No
h__h2_have_half_cap_results
No
h__h3_have_full_cap_results
No
h__h3_have_half_cap_results
No
h__h1_min_cap_heat_cap_rated
3200 W
h__h2_ext_cap_heat_cap_rated
14580 W
h__h1_half_cap_heat_cap_rated
7750 W
h__h2_is_capable_extended_load
Yes
c__low_temp_min_cap_power_rated
555 W
c__t1_min_cap_cooling_cap_rated
3250 W
c__low_temp_half_cap_power_rated
1230 W
c__t1_half_cap_cooling_cap_rated
7350 W
c__low_temp_have_half_cap_results
Yes
c__low_temp_min_cap_cooling_cap_rated
3720 W
c__low_temp_half_cap_cooling_cap_rated
7450 W

New Zealand E3 registration details

Registration number
ZAC0825
GEMS registration id
173586
Status
approved, available (self-reported)
Registration expires
n/a (NZ registration)
Registered for sale in
New Zealand
Family
–
Regulatory standard
[SEER Non Multi-Split <=65kW] (Air Conditioners up to 65kW) EE Regulations 2020 Schedule 2A
Test standard
AS/NZS 3823.1.2:2012
MEPS
2019
Product class
Class 11

Source: E3 programme registration data (EECA, New Zealand) (trans-Tasman E3 registration data published by DCCEEW on data.gov.au, CC BY 3.0 AU). Dataset published 19 September 2026; last checked 20 September 2026. How the derived figures are calculated.